Window grommet 3C2V, 22cm
Product descriptionThe window grommet is designed for pulling the coaxial cable through the window without drilling. It is a practical method of cable routing that is quick and easy. The grommet is fitted with practical F connectors at both ends.Product benefitsMounting the aerial lead without drilling the window frame. The cable can be screwed into the window without damage. More information
Availability:
In stock at manufacturer
Order. number:
18EMO01025
Weight:
0,05 kilogram
Code:
S5378
2,30 €
2,78 € incl. VAT
Product description
The window grommet is designed for pulling the coaxial cable through the window without drilling. It is a practical method of cable routing that is quick and easy. It is fitted with practical F connectors at both ends.Product advantages
Installation of the antenna lead without drilling the window frame. The cable can be screwed into the window without damage.- APE = air dielectric: no
- insulation colour of power supply conductors: not applicable
- cable sheath colour: white
- Shortening factor: 0,81
- dielectric type, diameter: PE 1,6 mm
- recommended connector types - F crimp: not applicable
- recommended connector types - F screw connector: not applicable
- FPE = foam dielectric: not applicable
- weight (kg/km): not applicable
- impedance: 75 Ohm
- insulation of power supply conductors: not applicable
- insulation resistance between cores at 20 °C (MOhm/km): not applicable
- capacitance (pF/m): 53
- design of power supply wires: not applicable
- cable sheath material: PVC
- shielding material: copper clad aluminium (CCA)
- inner conductor material: copper (Cu)
- max. equal resistance at 20 °C, (Ohm/km) - outer core: not specified
- max. equal resistance at 20 °C (Ohm/km) - inner core: not specified
- max. attenuation at 20 °C (dB/100m) 1000 MHz: not applicable
- max. attenuation at 20 °C (dB/100m) 100 MHz: not applicable
- max. attenuation at 20 °C (dB/100m) 10 MHz: not applicable
- max. attenuation at 20 °C (dB/100m) 2 000 MHz: not applicable
- max. attenuation at 20 °C (dB/100m) 450 MHz: not applicable
- max. attenuation at 20 °C (dB/100m) 650 MHz: not applicable
- max. attenuation at 20 °C (dB/100m) 860 MHz: not applicable
- min. bending radius single/multiple: not applicable
- min. reflection attenuation at 20 °C (dB) 10-300 MHz: not applicable
- min. reflection attenuation at 20 °C (dB) 300-600 MHz: not applicable
- min. reflection attenuation at 20 °C (dB) 600-900 MHz: not applicable
- min. shielding attenuation (dB) 10 ~ 800 MHz: not applicable
- Installation temperature: 5 °C to 60 °C
- hazardous substances: not subject to CPR
- UV resistant: yes
- PE = polyethylene dielectric: not applicable
- PES = film layer: not applicable
- number of shield wires: 32×0.12 mm
- number of shields: 1
- Shielding coverage: 28%
- sales packaging: 1 pcs, PE bag
- cable sheath diameter: 3 mm
- shielding diameter: 32×0.12 mm²
- Inner wire diameter: 0.5 mm
- cross-section of power supply wires: not applicable
- Storage temperature: -20 °C to 75 °C
- I.foil shielding: no
- Shielding II. foil: none
- reaction to fire class: not subject to CPR
- coaxial cable type: 3C2V
- suitable for outdoor use: yes
- intended use: replacement of wall drilling
- warranty period: 2 years
- packing method - length: 22 cm
- method of packaging - metre marking: not applicable
- packaging method - coil type: not applicable